The N 150Nm3 Membrane Nitrogen Generator for Laser Cutting
The N itrogen generator customized for laser cutting application can help to save gas usage costs, improve processing efficiency, enhance product quality, and enhance customer market competitiveness.
Sr# | Item | Indicators | Remarks: |
1 | N2 flow rate | 150Nm³/h | Rated flow rate of nitrogen varies with nitrogen purity |
2 | N2 purity | 90-99% |
3 | N2 outlet pressure | 1.4±0.1MPa | |
4 | Dew point: | ≤-40℃ | Meet the requirements of high-power laser cutting |
5 | Nitrogen dust filter diameter | 0.01um |
6 | Oil content in N2 | ≤0.003ppm |
7 | Total power | <51kw | Power for the whole package |
8 | Designed service life | 10years |
Public engineering facilities and consumption |
Air compressor | Rated Power 45kw 380V/50Hz Three phase four wire system (recommended to use 25mm2 wire) |
Refrigeration dryer | Rated power 2.4kw 1PH/AC220V/50Hz (≥1.5mm2, 1.5mm2 power line suggested) |
PSA N2 generator | Rated power 3.0kw 1PH/AC220V/50Hz (≥1.5mm2, 1.5mm2 power line suggested) |
Either HPD Dryer or adsorption dryer | Rated power 0.06kw 1PH/AC220V/50Hz (≥1.5mm2, 1.5mm2 power line suggested) |
Operating environment: | Max temp<40℃,Min temp>-15℃,Max humidity<80% |
cha racteristics:
◎Stable flow rate, controllable purity, with various auxiliary controls added. The flow rate can be measured and adjusted as needed, and the purity accuracy is controlled within ± 1%;
◎Fully covering the cutting needs of commonly used boards, equipped with up to 7 processing modes;
◎The overall safety factor of the equipment operation is high, and a delay electromagnetic valve is used to protect the impact of air (gas source) on the nitrogen generator, which can effectively adjust the nitrogen production efficiency of the nitrogen generator;
◎There are various safety control instruments such as pressure sensors, gas flow meters, and nitrogen purity analyzers installed on the gas supply pipeline to achieve the safe start stop and alarm functions of the entire nitrogen production equipment. The integration degree of the entire nitrogen production equipment configuration is very high.